Overview
D.61 on a Vaillant EcoTEC Plus Regular boiler is a diagnostic display code that refers to the number of unsuccessful lockouts the boiler has recorded. It is not a single fault description like an F-code; instead it indicates the boiler has repeatedly tried and failed to operate safely and has entered lockout protection multiple times. Those unsuccessful lockouts are usually the result of recurring ignition failures, flame losses, safety trips (overheat, flow/return sensor problems), gas supply interruptions or repeated safety-related faults. Because lockouts are a safety feature, D.61 is a sign that something persistent is preventing normal operation. Severity depends on what caused the lockouts: if it was a temporary gas supply glitch or a one-off ignition hiccup, it may be low severity and solved by simple checks and a reset. If the boiler keeps locking out, it is medium-to-high severity and requires diagnosis by a Gas Safe registered engineer. Homeowners can do basic visual and safety checks and try a controlled reset, but internal ignition, gas valve, PCB, electrode, pump or heat-exchanger related faults should only be handled by a qualified professional.
Possible Cause: Number of unsuccessful lockouts
Troubleshooting Steps
Safety precautions:
1) If you smell gas, evacuate the building immediately, do not operate electrical switches or the boiler, ventilate if safe to do so, and call the gas emergency number or your gas supplier immediately. Do not try to relight or reset the boiler.
2) If you see water leaks, excessive smoke, or signs of overheating, isolate the boiler electrical supply and call a Gas Safe engineer.
3) Only perform external, non-intrusive checks. Do not open the boiler casing or attempt internal repairs—these must be done by a Gas Safe registered engineer.
Initial checks a homeowner can do:
1) Note and record the exact display messages: the D.61 plus any F-codes or other messages shown before or after it. This information is valuable for the engineer.
2) Check boiler pressure on the gauge. Typical operating pressure is around 1–1.5 bar when cold. If pressure is below 1.0 bar, top up using the filling loop following the manufacturer’s instructions, then try a reset.
3) Check the mains gas supply: confirm other gas appliances (hob, gas fire) are working. If no gas to the property, contact your gas supplier.
4) Check the condensate discharge pipe (external frost blocks are common in cold weather) and the flue terminal for visible obstructions (birds' nests, debris). Clear any visible blockage at the external end only if safe to do so.
5) Check for obvious signs of electrical issues: blown household fuses/trips, the boiler’s fused spur switched on, and any water ingress or corrosion on external cable entries or the flue area.
Specific diagnostic and fix steps (homeowner-level):
1) Reset procedure: locate the boiler reset button (refer to your manual). Press and hold for the time recommended by the manual (commonly a few seconds up to 10s). Observe whether the boiler attempts ignition and whether the error clears. Do not repeatedly reset more than twice—if the boiler locks out again, leave it off and call an engineer.
2) If the reset clears and the boiler runs normally, monitor it for repeated lockouts and note any conditions when lockouts happen (calling for hot water, low load, cold start, etc.). If the problem reoccurs, record date/time, external temperature, and any other error codes shown and contact an engineer.
3) If pressure was low and you topped up and the boiler still locks out, do not keep resetting. Low pressure can be a symptom of a leak or failed component that needs professional attention.
4) If you found a blocked condensate pipe and safely cleared it, test the boiler with a reset. Frozen or blocked condensate is a common cause of repeated lockouts in cold weather.
5) Check room thermostat, programmer/timers and any wireless controls to ensure they are calling correctly; an intermittent control signal can cause unexpected behavior.
When to call a professional and what to tell them:
1) Call a Gas Safe registered engineer if the D.61 remains after basic checks and a controlled reset, if the boiler locks out repeatedly, if other F-codes are present, or if you suspect ignition, gas valve, electrode, PCB, pump, or heat-exchanger faults.
2) Provide the engineer with the boiler model, serial number, the D.61 diagnostic reading, any accompanying F-codes, a description of what you observed, times of lockouts, recent maintenance history and any steps you have already taken (pressure top-up, condensate cleared, reset attempts).
3) The engineer will perform safe, specialist diagnostics: check ignition sequence, flame signal and electrodes, gas pressure at the boiler, PCB and wiring harness, NTC sensors/flow and return sensors, pump operation and condensate/trap, flue and air supply, and then recommend repairs or parts replacement as required.
Final notes: D.61 is a diagnostic indicator that the boiler has undergone multiple safety lockouts — it should not be ignored. Basic safety and visual checks and a single controlled reset are acceptable for homeowners, but repeated lockouts or any signs of gas, water leaks, overheating, or persistent fault codes require immediate attention from a Gas Safe registered engineer. Do not attempt internal electrical or gas repairs yourself.
Helpful Resources
Vaillant ecoTEC Plus - Repairing a Faulty PCB to fix F61 / F62 & other F6n F7n errors.
video
Vaillant Ecotec Boiler, Common Faults
video
[Solved] Vaillant EcoTEC Plus - the motherboard has a ...
forum
Vaillant Boiler Error/Fault Codes - & How to Fix Them
article
Vaillant F61 Error Code: Expert Guide For Fixes
article
Boiler Manual
Download the official PDF manual for the Vaillant EcoTEC Plus Regular Gas Boiler.