D.75 on a Vaillant EcoTEC Plus regular boiler is a diagnostic message meaning the boiler reached the maximum allowed charging time while trying to heat a hot water storage cylinder that does not have its own controller. In plain terms the boiler attempted to bring the cylinder up to temperature but either the cylinder did not reach the required temperature within the preset time or the control/sensor that confirms the cylinder is hot did not report correctly. The boiler stops the charging attempt to avoid continuous running. This fault commonly occurs because of a faulty cylinder thermostat or temperature sensor (NTC), a failed or blocked pump or a closed/partially closed isolation valve to the cylinder, air in the primary circuit, or wiring/communication problems between the cylinder sensor and the boiler. It can also appear if the cylinder itself is very large relative to the expected charging time or if the boiler’s sensor is slow to respond. The result is loss of domestic hot water (or prolonged charging cycles) while central heating may continue to operate normally. Severity is medium: it is not usually an immediate safety emergency like a gas leak, but it does stop reliable hot water and indicates a component or plumbing fault that needs investigation. Some basic checks and a reset are reasonable for a competent homeowner, but anything requiring opening the boiler, working on gas/electrical components, or replacing sensors and pumps should be left to a Gas Safe registered engineer.
Possible Cause: Maximum charging time for a storage without own controller
Troubleshooting Steps
Safety precautions
- If you smell gas, stop, ventilate the area and call the gas emergency service immediately; do not operate the boiler.
- Before inspecting electrical connections or the inside of the boiler, switch the boiler off at the mains and isolate power. Do not open the boiler casing unless you are qualified.
- Do not attempt any gas, combustion, or high-voltage work unless you are a Gas Safe registered engineer.
Initial checks a homeowner can do
1. Record the error and any other codes shown. Try a simple reset: follow the boiler’s reset procedure (hold reset for several seconds) and see if the D.75 clears. Do not repeatedly reset the boiler if the fault returns.
2. Check the boiler water pressure on the gauge. Typical pressure when cold is about 1.0–1.5 bar. If pressure is low, you can top up using the filling loop per the boiler manual, then re-check for the fault. Ensure the filling loop valves are closed and secured after topping up.
3. Check the domestic hot water controls: make sure the cylinder thermostat (if accessible) and any programmer/room stats are set to call for hot water. If a separate cylinder thermostat or programmer is fitted, ensure it has power and is set correctly.
4. Listen for pump operation when hot water demand is on: you may hear the pump running. If you hear unusual rumbling or no pump sound when there should be flow, that suggests a pump problem or blocked flow.
5. Check visible isolation valves to the cylinder or plate heat exchanger are open. If your system has manual valves on the flow and return to the cylinder, ensure they are not closed.
6. Bleed radiators if circulation seems sluggish (air in the system can reduce flow to the cylinder).
Specific diagnostic and fix steps (do not open the boiler)
1. After initial checks, make a single reset of the boiler and run a hot tap for several minutes while watching the boiler display: note whether the boiler attempts to charge the cylinder and whether temperature indications change. If the boiler makes no charging attempt, note any other faults or lack of pump noise.
2. If topping up pressure cleared the fault and the boiler now charges the cylinder normally, monitor pressure over the next days. Repeated pressure loss indicates a leak or expansion vessel problem and requires an engineer.
3. If the boiler attempts to charge but never reaches temperature before timing out (D.75 returns), the likely causes are a faulty cylinder sensor/thermostat, blocked primary flow to the cylinder, or a pump fault. At this point avoid trying to remove or replace sensors yourself.
4. If you have an external cylinder thermostat unit (not inside the boiler) you can check visually that it has power and its setpoint/timer is correct. If you are comfortable and trained, you may check for loose external wiring connections with the power isolated; otherwise leave this to the engineer.
5. If you see other codes such as F75 (pressure/pump related) alongside D.75, mention both to the engineer: one code may point to pressure or pump issues while D.75 indicates charging timeout.
When to call a professional
- Call a Gas Safe registered engineer if the code persists after the simple checks above, if you find evidence of pump failure or blocked flow, if electrical or sensor wiring appears faulty, or if you need the boiler opened for diagnosis or part replacement.
- Tell the engineer the boiler model, the D.75 diagnostic, any other displayed codes, what you tried (reset, topped up pressure, checked valves, listened for pump), and whether you have a separate cylinder thermostat.
What the engineer will typically do
- Verify fault using diagnostic menus/logs, check cylinder NTC or thermostat operation and replace if faulty, inspect and test the primary circulation pump, check flow/return isolation valves and any plate heat exchanger for blockages, verify system pressure and expansion vessel condition, and inspect wiring/PCB connections.
Final notes
- Avoid repeated resets; persistent faults should be addressed by an engineer to avoid causing further damage.
- Do not attempt gas or internal electrical repairs yourself. Calling a qualified engineer is the safe route if the basic homeowner checks do not clear the fault.